Raymarine S1000 Fish Finder User Manual


 
S1000 Autopilot Installation Guide 25
D7549-1
Purple
Red
Black
White
NMEA connector (not
supplied), from GPS
GPS requirement
The S1000 must receive GPS information to
function correctly. Use the Data Cable supplied,
to connect the Course Computer to a GPS, using
either of the following methods:
1. To a Raymarine GPS via SeaTalk connections.
2. To a Raymarine GPS via NMEA spur.
3. To a non-Raymarine GPS via NMEA spur.
Safety
alarm
NMEA Spur
Course Computer
Data
cable
For details of the NMEA Spur
connections, refer to Diagram D
When connecting NMEA data from an external source, always
connect via the NMEA spur on the Data Cable. Do NOT connect
NMEA data from an external source directly to the connector on
the Course Computer.
When you have completed the electrical connections,
secure the wires at the Course Computer.
Connector
block
Clip ferrite to
Data Cable,
as close to
the connector
as possible
If you want to connect to an external SeaTalk system, ensure each of these
SeaTalk wires connects to the wire of the same color in the external system.
Yellow: SeaTalk Data
Red: SeaTalk +12 V
Black: SeaTalk 0 V
SeaTalk
Each time power is applied to an S1000 Autopilot connected to a
Raymarine GPS (via NMEA or SeaTalk), the S1000 will set the GPS
filtering to WEAK.
Diagram C: Connecting the Data Cable
87040_5.book Page 25 Monday, April 30, 2007 5:58 PM