Sierra 840 Marine Sanitation System User Manual


 
Appendix A Series 830/840/860 Instruction Manual
A-4 IM-83/84/86-H
Where:
H = The constant amount of heat applied to the sensor tube,
m = The mass flow rate of the gas (gm/min)
Cρ = The coefficient of specific heat of the gas (Cal/gm);
Cρ is given in the Table (at 0°C),
T = The temperature difference between the downstream and
upstream coils, and
N = A correction factor for the molecular structure of the gas
given by the following table:
Number of Atoms in the Gas Molecule
N
Monatomic
1.040
Diatomic
1.000
Triatomic
0.941
Polyatomic
0.880
The mass flow rate, m, can also be written as:
m = Q
!
(3)
Where:
ρ = The gas mass density at standard conditions (g/l); ρ is given
in the tables (at 0°C, 760 mm Hg).
Furthermore, the temperature difference, T, is proportional to the
output voltage, E, of the mass flow meter, or
T = aE (4)
where:
a = A constant.
If we combine equations (3) and (4), insert them into equation (2),
and solve for Q, we get
Q = (bN/ρC
p
) (5)
where:
b = H/aE = a constant if the output voltage is constant.