3.7. Vie wing Alarm Mes sa ges
&
An alarm is gi ven by stea dy light of the “alarm” lamp.
Pres sing the “Reset” key era ses the stea dy light of the
“alarm” lamp (the “alarm” lamp goes off). The fai lu re is not re -
pai red.
F
Fai lu res must be re pai red im me di ate ly.
Pos si ble events:
- Fault hop per
In the ope ra ting mode “pro be con vey ing”, the le vel of ma te ri al has not rea -
ched the pro be wit hin the set con vey ing time.
Pos si ble cau ses: lack of ma te ri al, fal se con vey ing time set ting or de fec ti ve pro be.
In the ope ra ting mode “time-controlled con vey an ce”, no sig nal chan ge of the
flap switch has oc cur red wit hin the set emp ty ing time.
Pos si ble cau ses: lack of ma te ri al, fal se emp ty ing time set ting or de fec ti ve flap.
816-4MS
Vie wing Alarm Mes sa ges
Start-up 3-8