3.1. Method of func tion ing
The sin gle con veyor unit works ac cord ing
to the venturi prin ci ple. An ex ter nal com -
pressed-air sup ply is needed.
A venturi me ter (A) is in te grated in the in -
jec tor tube. The venturi me ter as pi rates
the ma te rial in the lower part of the tube (C)
and then con veys the ma te rial into the con -
veyor hop per by means of com pressed air
in the up per part (B). In the hop per loader,
the ma te rial is sep a rated from the air.
The fill ing level in the con veyor hop per is
mon i tored and con trolled by means of a
level probe.
3.2. Con trol and main te nance unit
The unit is switched on and off at the con trol and main te nance unit.
On the pres sure re ducer, the op er at -
ing pres sure is ad justed. A wa ter sep -
a ra tor is in te grated.
006-4MS
SSV 05
Func tional de scrip tion 20