NOTE: When deepstops are enabled, the length of mandatory
safety stops is indicated in seconds.
When the ascent rate exceeds 10 m (33 ft) per minute for more than
five consecutive seconds, the microbubble build-up may be more
than is allowed for in the decompression model.
In this situation, Suunto Zoop Novo adds a mandatory safety stop to
the dive. The time of this stop depends on the speed violation of
the ascent rate.
The STOP icon is shown in the display. When you reach the depth
zone between 6 m and 3 m (18 ft and 9 ft) the following is
displayed:
1.
CEILING
and
STOP
2. Ceiling depth
3. Safety stop time