Command parameters
For those parameters that contain data only in the RAM and not in the EEPROM, their data return to
initial values when the power is turned off, in failure resetting, or when standard shipment settings
are set. Note that parameters without data storage in the EEPROMs will be written in the RAM only
even if the command W (writing in EEPROMs and RAM) is executed.
Q Commands                          NOTE : Data is expressed in decimal notation.
C
ommunica
-
tion
Num-
ber.(HEX)
Function
Adjustment Range
Min.
Setting
Unit
Initial
Value
Write
During
O
pe
r
atio
n
EEP
ROM
FA00
Command 1 (2-wire RS485)
1
0 to 65535 0yesNone
FA01 Frequency command value (2-
wire RS485)
1
0 to Max. frequency
()
0.01Hz 0 yes None
FA03 Operation panel operation
frequency *
2
Low-limit frequency
() to High-limit
frequency ()
0.01Hz 0 yes Available
FA04
Command 1 (4-wire RS485)
1
0 to 65535 0yesNone
FA05 Frequency command value (4-
wire RS485)
1
0 to Max. frequency
()
0.01Hz 0 yes None
FA10
Panel key selection
4
0: Main unit
1: Comunication
0yesNone
FA11 External communication key
data
4
0 to 65535 0yesNone
FA20
Command 2 (2-wire RS485)
1
0 to 65535 0yesNone
FA22
Command 2 (4-wire RS485)
1
0 to 65535 0yesNone
FA30 Torque command value (2-wire
RS485)
-250.00 to 250.00 0.01% 0 yes None
FA32 Torque command value (4-wire
RS485)
-250.00 to 250.00 0.01% 0 yes None
FA50
Terminal output data
3
0 to 255 1 0 yes None
FA51
FM analog output data
3
0 to 2047
(11-bit resolution)
10yesNone
FA52
AM analog output data
3
0 to 2047
(11-bit resolution)
10yesNone
FA53
MON1 analog output data
3
0 to 2047
(11-bit resolution)
10yesNone
FA54
MON2 analog output data
3
0 to 2047
(11-bit resolution)
10yesNone
FA65 Select display by communica-
tion
4
0 to 2 1 yes Available
FA66
Numerical display data
4
0-9999 1 0 yes Available
FA67
Decimal point position
4
0 to 2 0 yes Available
FA68
LED data for unit 0
4
0 to 3 0 yes Available
FA70 ASCII display data 1
First digit from left
4
0 to 127 100
(‘d’)
yes Available
FA71 ASCII display data 1
Second digit from left
4
0 to 255 65
(‘A’)
yes Available
FA72 ASCII display data 1
Third digit from left
4
0 to 255 116
(‘t’)
yes Available
FA73 ASCII display data 1
Fourth digit from left
4
0 to 127 65
(‘A’)
yes Available
FA74
LED data for unit1
4
0 to 3 0 yes Available
FA75 ASCII display data 2
First digit from left
4
0 to 127 48
(‘0’)
yes Available
FA76 ASCII display data 2
Second digit from left
4
0 to 255 48
(‘0’)
yes Available
FA77 ASCII display data 2
Third digit from left
4
0 to 255 48
(‘0’)
yes Available
FA78 ASCII display data 2
Fourth digit from left
4
0 to 127 48
(‘0’)
yes Available
FA79
LED data for unit 2
4
0 to 3 0 yes Available
FA80
Block communication mode
4
0 to 1 0 yes Available