To adjust the low battery shutdown setting:
By default the low voltage setting is set to Low (“”).
Low (“”) sets the low battery shutdown threshold to 10.5 V
for all models except Freedom HF 1500.
Middle (“”) is only available to Freedom HF 1500 and
Freedom HF 1800 T. It sets the low battery shutdown threshold
to 12.1 V and 11.8 V respectively.
High (“”) sets the low battery shutdown threshold to 11.8 V
for all models except Freedom HF 1800 T which sets the low
battery shutdown threshold to 12.1 V.
See “Shutdown Settings” on page 3 for a summary.
1. Press and hold the Inverter Power button for five seconds.
2. Press the Inverter Power button three times.
The LED screen will flash “” intermittently.
3. Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. Example, “” for a low shutdown voltage
setting.
4. Continue pressing the Select button to cycle through the two –
” and “” settings (or through three settings
a
) until you
reach the desired setting.
5. Press and hold the Select button for five seconds to make the
setting permanent.
To return all feature settings to factory default settings:
1. Press and hold the Inverter Power button for five seconds.
2. Press the Inverter Power button four times.
The LED screen will flash “” intermittently.
3. Press and hold the Select button for five seconds to return all
feature settings to their factory default settings.
a.In addition to two settings “” and “”, the middle setting “” is available
only for Freedom HF 1500 and 1800 T models (PNs: 806-1544, 806-1840, 806-1840-
01).
Freedom HF InvChg Owners Guide.book Page 14 Tuesday, April 29, 2014 12:10 PM