Xantrex Technology Link 2000 Marine Instruments User Manual


 
38
The VIOLET WIRE (B2 V) supplies Battery #2 voltage for sensing. It should be supplied
directly from Battery #2. Be sure to install the 2-amp fuse shown in the drawing.
NOTE: If only one battery is to be monitored, connect the VIOLET wire to
the BLUE wire.
The GREEN WIRE (B1SHG) is connected to the SMALL SCREW ON THE GROUND
SIDE, OR LOAD SIDE, of the battery #1 shunt (B1SHG). This wire must be located
exactly as described to ensure accuracy of current measurements. The wires that run
from the battery #1 shunt sense terminals to the GREEN AND ORANGE wires should
be a twisted pair.
The ORANGE WIRE (B1SHB) is connected to the SMALL SCREW ON THE
BATTERY SIDE of the battery #1 shunt (B1SHB). This wire should be located exactly
as described to ensure accuracy in current measurements.
NOTE: If only one current input is used, connect the Green and Brown wires
together and the Orange and Yellow wires together. This hookup will display the
same current information for both the battery #1 and #2 selection.
The BROWN WIRE (B2SHG) is connected to the SMALL SCREW ON THE
GROUNDED, OR LOAD SIDE, of the battery #2 shunt (B2SHG). SEE ABOVE
CAUTIONS.
The YELLOW WIRE (B2SHB) is connected to the SMALL SCREW ON THE
BATTERY SIDE of the Battery #2 shunt (B2SHB). The YELLOW and BROWN wires
should be a twisted pair. SEE ABOVE CAUTIONS.
THE INVERTER REMOTE CABLE
The only connection between the Freedom and the Link Control Panel is a standard
remote cable. There are three jacks on the back (bottom) of the inverter. Use the one labeled
REMOTE. It is best to plug the remote cable into the LINK 2000 after it is powered up.
It is supplied with a 25' cable. You may purchase longer cords from any telephone supply
company. You should limit its length to 50 feet. Do not run the remote cable in the same
wireway as very noisy power conductors. This helps reduce noise interference problems.