Resetting After a Fault or Shutdown
975-0054-01-01 3–9
Resetting After a Fault or Shutdown
This section provides explanations and procedures for resetting the
XS400 after a fault or shutdown.
If you are unable to resolve the problem after referring to Table 3-3, refer
to the “Troubleshooting” section on page 4–2.
Table 3-3
Resetting After A Fault or Shutdown
Fault Status Action
Shutdown The XS400 needs to be reset. Turn the On/Standby switch on either the
inverter’s front panel or the S400 Remote
Switch to Standby ( ) and then to On ( ).
Short circuit If there is a short circuit, the
Supplemental Circuit Protection
button trips.
Remove the short circuit then press the
Supplemental Circuit Protection button.
Ground Fault When a fault condition is
detected, the Reset button on the
GFCI outlet trips and power to the
appliances is interrupted.
Reset: To resume normal operation,
determine and correct the ground fault,
then press the Reset button.
Test: Press the Test button on the GFCI
outlet with either shore power and/or the
XS400 turned to On ( ). The Reset button
should trip. Press the Reset button to reset
the GFCI and to continue with normal
operation. This test should be performed
on a monthly basis.
If the Reset button does not trip, the GFCI
may have failed. Contact your dealer to
have a qualified service person examine
the XS400.
Overload The XS400 is designed to provide
400 watts continuously and 800
watts surge capability for five
seconds. If the connected
appliances draw more than the
rated power, the XS400 will shut
down and the red Fault light
illuminates.
Disconnect the appliances connected to
the inverter and then turn the On/Standby
switch on either the inverter’s front panel
or the S400 Remote Switch to Standby
( ) and then to On ( ).
See also “Recharging Your Batteries
When Low Battery Light Illuminates” on
page 3–6.