Furuno 1933 Marine RADAR User Manual


 
4-5
4.2.2 Connecting remote display
The FURUNO Display unit FMD-811, MODEL1832 or GD-280/380, etc. can be connected
to the NavNet display as remote display. To interconnect them, use a cable attached with or
set as option for the remote display.
1. Unscrew six connecter nuts at the rear of the display unit.
2. Unfasten 16 binding screws (M3x10) to remove the display cover.
3. Remove the connector cover at the rear of the display cover.
4. Pass the signal cable for remote displaying through the hole, and then connect the XH
connector (8P) of the signal cable to J105 on the SPU Board. If your remote signal cable
has the ground wire, put it outside of the display cover and fix it with the pan head screw
shown below.
Connector Nut
5 pcs.
24P Connector Nut
(Large) 1 pc.
(Small) 4 pcs.
J105
SPU Board
Remove
connector cover.
Cable tie
Use this pan head screw
to fix the ground wire of
the remote signal cable.
How to connect remote signal cable
5. Attach the cable tie supplied as installation material to the position shown above, and
then tie the cable with it.
6. Reassemble the display unit.
7. Apply soft putty to seal the hole at the rear of the display unit.