AP-6
Board Switch Setting Function
Factory
setting
#1 #2 Ship’s speed for distance run pulse selection
OFF OFF
Speed over-the-ground & through-water & speed
fed from nav sensor
○
OFF ON Speed over-the-ground & through-water
ON - Speed through-water
OFF Type of ship’s speed for distance run pulse: Vector
○
#3
ON Ditto : Fore-aft
OFF Bearing data output: True course
○
#4
ON Ditto : Heading
OFF Bearing data output at low Ship’s speed: True course
○
#5
ON
Ditto :Heading
(Since ship’s course data fluctuates by rolling and
pitching when ship’s speed is extremely low,
heading data is output instead of course. )
OFF Distance signal alarm Contact: ON = No alarm
○
#6
ON Fore-aft status Contact: ON = Aft (note 1)
OFF CIF/NMEA 1 option data: Off
◎
#7
ON Ditto : On (Note 2.)
OFF CIF/NMEA 2 option data: Off
◎
S4
#8
ON Ditto : On (Note 2.)
S5 0 to F Engine revolution full scale setting.
0 Rate-of turn gyro data averaging time: 10 mses
1
Ditto
: 20mses
2
Ditto
: 40mses
3
Ditto
: 80mses
4
Ditto
: 160mses
5
Ditto
: 230mses
◎
6
Ditto
: 640mses
MIF Board
S6
7 to F
Ditto
: 1280mses
Note 1:
Prior to setting #6 to “ON”, set #3 to “ON”.
Note 2: