Furuno FA-100 Marine RADAR User Manual


 
18
3.5 LAN Input/Output
The FA-100 supports Ethernet based on LAN. Its protocol is 10BASE-T and the
transmission rate is 10 Mbps. To connect the FA-100 with other equipment (such as
a PC), use a LAN cable category 4 or higher with shield (SDT). Connect it to the
PC with an RJ-45 connector, and connect to the FA-100 with a D-sub 9 pin
connector, to avoid noise leakage. To use a commercial LAN cable, remove one
connector and solder a D-sub 9 pin connector, supplied in the installation materials.
TD+
TD-
RD+
RD-
GND
F.GND
LAN (10B-T)
FA-100
>1>
>2>
>3>
>4>
>8>
>9>
3 RD+
6 RD-
1 TD+
2 TD-
Twisted pair cable
RJ-45 (Category 4 and higher, SDT)
3.6 Pilot Plug
Use the twisted cable TTYCS-4 between the junction box and the pilot plug. The
cable between the PC and the pilot plug should be prepared by the ship’s pilot.
Junction box
Terminal board
TD A
TD B
RD-A
RD-B
SHIELD
TB1
>1>
>2>
>3>
>4>
>5>
>6>
>7>
>8>
>9>
J1
37 TD8-A
38 TD8-B
39 GND ISO
40 RD8-A
41 RD8-B
42 GND ISO
Pilot plug
TTYCS-4
3mm Crimp-on lug
206486-1
(AMP)
PC