Furuno FE-700 SONAR User Manual


 
20
3. CHANGING POWER
SPECIFICATIONS
This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100
VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connections in the distribution
box as shown below.
Note: Tick the appropriate box on the inside of the FE-702 distribution box cover to denote the
power use.
200-230 VAC (50/60 Hz)
100-115 VAC (50/60 Hz)
24 VDC
Label inside the distribution box FE-702
100 VAC, 110-115 VAC, 200 VAC Ship's Mains
1. Connect the power cable to #1 & #3 on TB5 in the distribution box.
2. Modify the wiring at TB7 according to ship's mains as shown in the table below.
Ship's mains TB7 #1 TB7 #2 TB7 #3 TB7 #4 TB7 #5
220-230 VAC
(Default)
Orange Red Black Brown White
200 VAC Red Orange Black Brown White
110-115 VAC Black Red Orange Brown White
100VAC Brown Red Black Orange White