2. WIRING
2-6
2.4 IF Unit
The IF unit installs between the processor unit and the transceiver unit. Connect the
cables according to the diagram inscribed on the shield cover of the IF unit. JIS cables
and FURUNO cables are available for the connection. To connect the JIS cables, use
the larger cable holes as shown below.
Select a location that provides the maintenance space prescribed in the outline draw-
ing. Follow the compass safety distance in the Safety Instructions to prevent interfer-
ence to a magnetic compass.
*: JIS=Japan Industrial Standard. See the appendix for equivalent cable.
Connection point Cable type See (1) below See (2) below Remarks
Ext. KP JIS cable* 400 mm 100 mm
FURUNO cable 400 mm 120 mm
Gyro JIS cable* 400 mm 100 mm
FURUNO cable 400 mm 100 mm
Transceiver Unit FURUNO cable 400 mm 100 mm Standard supply
CIF1 JIS cable* 400 mm 100 mm
FURUNO cable 400 mm 100 mm
CIF2 JIS cable* 400 mm 120 mm
FURUNO cable 400 mm 120 mm
Control Unit
Cable entrance for
external equipment
Processor Unit
(19S1050, 3 m)
Processor Unit
(10S2383, 3 m)
10S2884
(5/10 m)
Ground wire
(local supply, IV-2sq)
Gyrocompass (GYRO)
䋨TTYCSLA-4 or equivalent䋩
Transceiver Unit (TRX)
䋨10S2380 or equivalent䋩
External KP (EXT KP)
䋨MPYC-12 or equivalent䋩
CIF1
CIF2
Not used.
CIF1 or CIF2
(TTYCSLA-1 or equivalent)
45
5
(1)
(2)
5
Braided
shield
Core
Sheath
Armor
5
Aluminium tape
㪫㪫㪰㪚㪪㪣㪘
㪤㪧㪰㪚
(1)