Service
30 312865R
Trip Rod Repair
(SDP5 & SDP15 Meters Only)
Disassembly
1. Relieve Pressure, page 9.
2. Use a Torx (T20) wrench to remove 4 corner screws
(A) located on the bottom of the meter (F
IG. 30).
Keep these screws for reassembly.
3. Turn meter over and tilt cover back (F
IG. 31).
4. With your finger, carefully
lift up clip (D) to discon-
nect battery lead (B) from battery module.
5. Unsnap solenoid lead (C) (F
IG. 33).
FIG. 30
You will not be able to completely remove the cover
until you disconnect the leads to the battery, sole-
noid and remove the reed switch PCB.
F
IG. 31
A
A
ti11936a
ti11937a
B
C
FIG. 32
NOTICE
Do not use a screw driver or any other tool to lift up
clip (D) when disconnecting battery lead (B) from bat-
tery module. If the clip is damaged or broken it cannot
be repaired; you will have to replace the battery mod-
ule. Order Part No. 255197.
F
IG. 33
B
ti11938a
D
D
ti11939a
C