Graco TI1962A Marine Sanitation System User Manual


 
Maintenance
11
Maintenance
Lubrication
Flushing and Storage
Flush the pump with a compatible solvent often enough
to prevent the fluid you are pumping from drying in the
pump and damaging it. Follow the Pressure Relief Pro-
cedure on page 10 before storing it for any length of
time.
Tighten Threaded Connections
1. Before each use, check all hoses for wear or dam-
age, and replace as necessary.
2. Check to be sure all threaded connections are tight
and leak-free.
3. Check and re-torque all screws and fasteners at
least every two months. Re-torque the fluid cover
screws first, followed by the manifold screws.
NOTE: Before using pump, loosen fluid cover
screws (31) 1-2 turns and then re-torque to 20 N•m
(15 ft-lb).
Preventive Maintenance
Schedule
Establish a preventive maintenance schedule, based on
the service history of the pump. This is especially impor-
tant for prevention of spills or leakage due to diaphragm
failure.
CAUTION
Lubrication of the pump is not required. Oil is
exhausted through the muffler, which could contami-
nate the fluid supply or other equipment. Excessive
lubrication can also cause the pump to malfunction.