Graco TI1962A Marine Sanitation System User Manual


 
Technical Data
25
Technical Data
Category Data
Maximum fluid working pressure 1.8 MPa, 18 bar (260 psi)
Maximum air input pressure 0.6 MPa, 6 bar (88 psi)
Ratio 3:1
Maximum recommended flow rate (continuous duty) 7.6 liters/min (2.0 gpm)
Maximum recommended cycle rate 20 cycles/minute
Maximum flow rate 114 liters/min (30 gpm)
Volume per cycle (double stroke) 350 cc/cycle (11 oz/cycle)
Operating temperature range 10-80°C (50-176°F)
Dry suction lift 2.5 m (8.2 ft)
Wet suction lift 6.7 m (22 ft)
Air inlet size Model 253707: 1/2 BSPP(f)
Model 253708: 1/2 npt(f)
Fluid inlet size Model 253707: 1 in. BSPP(f)
Model 253708: 1 in. npt(f)
Fluid outlet size Model 253707: 1 in. BSPP(f)
Model 253708: 1 in. npt(f)
Sound power level at 15 cycles/min, 0.6 MPa, 6 bar (88
psi) air inlet pressure. Tested per ISO 9614-2.
66 dB(A)
Weight (approximate) 29 kg (64 lb)
Wetted parts 303 and 316 stainless steel, acetal, fluorocarbon,
ultra-high molecular weight polyethylene, PTFE