Icom IC-F3061T Marine Radio User Manual


 
6 - 6
6-4 RECEIVE ADJUSTMENT
Select an adjustment item using [
] / [
] keys, then set to the specifi ed value using [
] / [
] keys on the connected PC's keyboard.
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
RECEIVE
SENSITIVITY
[BPF T1 C]
[BPF T2 C]
NOTE:
"RECEIVE SENSITIVITY" must be adjusted before "S-METER." Otherwise, "S-METER" will not be
adjusted properly.
1
• Channel : CH 5
Multi
connec-
tor
Connect the SINAD meter
with an 8
load to the JIG
cable.
Minimum distortion
level
Connect the SSG to the antenna connec-
tor and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 155.000 MHz
: +20 dBµ
(–87 dBm)
: 1 kHz
: ±3.5 kHz
[BPF T1 H]
[BPF T2 H]
2
• Channel
Frequency
• Receiving
: CH 6
: 136.000 MHz
[BPF T1 L]
[BPF T2 L]
3
• Channel
Frequency
• Receiving
: CH 7
: 174.000 MHz
CONVENIENT:
The "RECEIVE SENSITIVITY" can be adjustment automatically.
1: Put the cursor on "BPF T1 C/L/H ALL" or "BPF T2 C/L/H ALL" and then push [ENTER] key.
2: The connected PC tunes BPF's to peak levels automaticaly.
or
1: Put the cursor on the one of "BPF T1 C/L/H" and "BPF T2 C/L/H" as desired.
2: Push [ENTER] key to start tuning.
3: Repeat 1 and 2 to perform additional BPF tuning.
S-METER
[RSSI]
1
• Channel : CH 6 Push the [ENTER] key on the connected PC's keyboard to set
"S3" level.
Connect the SSG to the antenna connec-
tor and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 136.000 MHz
: +23 dBµ
(–84 dBm)
: 1 kHz
:
±
3.5 kHz
2
• Set the SSG as;
Level
• Receiving
: –7dBµ
(–114 dBm)
Push the [ENTER] key on the connected PC's keyboard to set
"S1" level.
SQUELCH
[SQL]
1 • Channel : CH 5 External
speaker
Connect an 8
speaker to
the JIG cable.
Set the [SQL] to the
value that the audio
signals just appears.
• Close the squelch by adjusting the value of
[SQL] item on the CS-F3060 ADJ's screen.
Connect the SSG to the antenna connec-
tor and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 155.000 MHz
: –14 dBµ
(–121 dBm)
: 1 kHz
:
±
3.5 kHz
†;
The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.