8. Insert the new Power Distribution Board into the power supply cage (letter “A”). Try to route
the power cables to the appropriate area at the time of insertion (see Steps 9 and 10). Do not
secure the Power Distribution Board yet.
A
TP01996
Note: Cables on back of Power Distribution Board not shown to clarify insertion process.
Figure 64. Inserting Power Distribution Board in Power Supply Cage
9. Route the P1, P2, and P14 power cables to the server board and connect to appropriate
connectors. Refer to the Intel® Server Board Quick Start User’s Guide or User Guide for the
location of power connectors.
10. Route the longest power cables (P8, P9, P10, and P11) to the six-drive bay and connect power
cables to any installed devices. Route the shorter cables (P3, P4, and P5) to the upper device
bay and connect to any installed devices. Route the P6 and P7 cables to the four-drive bay and
connect to any installed devices. Route the SATA drive power cables to which ever drive bay