Technical Reference
Intel® Server Chassis SC5300 User Guide 61
System Environmental Specifications
Table 6. Environmental Specifications
Temperature
Non-operating
Operating
–40 ° to 70 °C.
5 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum
of 10,000 ft.
Humidity
Non-operating
90% relative humidity (non-condensing) at 30 °C.
Shock
Operating
Packaged
2.0 g, 11 msec, 1/2 sine
Operational after an 18” free fall.
Acoustic noise 7 Bels in sound power for a typical office ambient temperature (65-75
°F). Your selection of peripherals may change the noise level.
Electrostatic discharge (ESD) Tested to 15 kilovolts (kV); no component damage.