Kenwood 762G Marine Radio User Manual


 
14
TK-760G/762G
REALIGNMENT
No. Function
Choices Display Remarks
9 RF High power PWR_H___ Default
power Low power PWR_L___
10 Wide/ Wide WIDE____
Narrow Narrow NARROW__
11 Scan DELETE SCAN_DEL Not used for 8ch
Delete/Add
ADD SCAN_ADD Default
12 Priority No P.CH_NO__ Not used when (Scan)
channel Yes P.CH_YES_ priority is not fixed
13 Home No H.CH_NO__ Not used when home
channel Yes H.CH_YES_ channel is not set in
key assignment
14
Compander
No COMP_NO_ Not used when wide
is selected
Yes COMP_YES
15 PTT ID OFF P.ID_OFF_
Begin of TX P.ID_1___
End of TX P.ID_2___
Both P.ID_3___
16 Begin 000~ _BOT_ID_ Not valid if Dial ID=
of TX ID
9999999999999999
disable and PTT ID=
off, or EOT is set
Display when an item
is selected (about
0.5 seconds)
12345678 Display of the current
setting (If it is 8 or
more digits, scroll it)
- - - - - 987 Display when a code
is input (Input it with
DTMF key)
Blank - - - - - - - - [ ] : Data clear
17 End of 000~ _EOT_ID_ Not valid of Dial ID=
TX ID
9999999999999999
Idisable and PTT ID=
off, or BOT is set
Display when an item
is selected (about
0.5 seconds)
12345678 Display of the current
setting (If it is 8 or
more digits, scroll it)
- - - - - 987 Display when a code
is input (Input it with
DTMF key)
Blank - - - - - - - - [ ] : Data clear
No. Function
Choices Display Remarks
3 TX Step STP__250 Display when an item
frequency
2.5kHz~1MHz STP_1000 is selected or when a
step is changed
(about 0.5 seconds)
[A] : Step change
2.5, 5.0, 6.25, 7.5kHz,
1MHz step
Blank - - - - - - - - [ ] : Frequency on/
100.0000~ T.100.0000 blank switching
550.0000MHz The rightmost dot
indicates 50Hz digit
(On=5, Off=0)
4 TX Off - - - - - - - - [ ] : Off/QT/DQT
signalling
QT 67.0~250.3Hz
QT__67.0_ switching
(EIA mode) QT_250.3_ [A] : Mode switching
QT 67.0~250.3Hz
QT__67.0* [SCN] : Normal/
(0.1Hz step mode)
QT_250.3* Inverse switching
DQT 000~777 DQT000N*
(Normal) DQT777N*
(1 step mode)
DQT 023~754 DQT023N_
(Normal) DQT754N_
(Standard table mode)
DQT 000~777 DQT000I*
(Inverse) DQT777I*
(1 step mode)
DQT 023~754 DQT023I_
(Inverse) DQT754I_
(Standard table mode)
5 Option Off NONE____ Default
signalling
DTMF DTMF____
2-TONE 2TONE___
6 ID 000~ ___ID___ Display when an item
9999999999 is selected (about
0.5 seconds)
12345678 Display of the current
setting (If it is 8 or
more digits, scroll it)
- - - - - 987 Display when a code
is input (Input it with
DTMF key)
Blank - - - - - - - - [ ] : Data clear
7 Busy No BCL_NO__ Default
channel Type 1 BCL_1___ BCL_YES_ for K type
lockout Type 2 BCL_2___ Not used for K type
8 Beat No SHFT_NO_ Default
shift Yes SHFT_YES