Kenwood 762G Marine Radio User Manual


 
7978
LEVEL DIAGRAM
Receiver Section
Center Frequency 49.95MHz 450kHz Audio Frequency
Control Unit TX-RX Unit VCO Unit TX-RX Unit Power Module TX-RX Unit
To make measurements in the RF section, connect the RF
level meter.
In the RF section, use a 0.01µF coupling capacitor.
(The display shows the SSG input value required to obtain
12dB SINAD.)
To make measurements in the AF section, connect the AC level meter.
(ANT input : –53dBm, 1kHz FM, 3kHz DEV (Wide) / 1.5kHz DEV (Narrow))
The AF output level is adjusted for 0.45V/4 by the front panel AF VOL control.
To make measurements in
the RF section, connect the
RF wattmeter (50).
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
Transmitter Section