Oceanic 04-8930-07 Scuba Diving Equipment User Manual


 
32
OCL OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
High PO2 during Deco (Fig. 88)
The PO2 alarm settings do not apply when in Deco which has a xed alarm of 1.60 (ATA).
> If PO2 reaches 1.60 while at a Deco Stop, the PO2 value (1.60) with icon will alternate with Deco Stop Depth/Time
once each minute*.
*PO2 on for 10 seconds, Deco Stop Depth/Time on for 50 seconds until PO2 decreases below 1.60, then PO2 will
not be displayed.
HIGH O2 (NORM only)
Warning >> from 80% (240 OTU) up to 99%.
Alarm >> at 100% (300 OTU).
When O2 reaches the Warning Level; the audible sounds and the O2 value with icon will ash in place of DTR (Fig. 89)
until the audible is silenced, then DTR will be restored.
• S (< 2 sec) - to acknowledge alarm.
If O2 reaches the Alarm level; the audible sounds again and the Up Arrow icon and the O2 value with icon will ash in
place of DTR (Fig. 90) until on the surface.
• S (< 2 sec) - to acknowledge alarm.
• A (< 2 sec) - to access ALTs (similar to those for No Deco).
• M (< 2 sec) - to access Gas Switching.
• L (press) - to activate Backlight.
High O2 during Deco
When O2 reaches the Warning Level; the audible sounds and the O2 value with icon will ash in place of TAT (Fig. 91)
until the audible is silenced, then TAT will be restored.
• S (< 2 sec) - to acknowledge alarm.
If O2 reaches the Alarm level; the audible sounds again and the Up Arrow icon and the O2 value with icon will ash in
place of TAT until on the surface. Max Depth and EDT will be displayed in place of Deco Stop Depth/Time (similar to Fig.
90).
• S (< 2 sec) - to acknowledge alarm.
• A (< 2 sec) - to access ALTs (similar to those for No Deco).
• M (< 2 sec) - to access Gas Switching.
• L (< 2 sec) - to operate the Backlight.
High O2 on Surface
Upon ascent to 2 FT (0.6 M) for 1 second (surfacing), the Dive Main screen is displayed for 10 minutes with access to the
Dive ALTs allowed.
• If O2 is 100%, the value will ash on the Main until it is < 100%, then it will be replaced with dashes (if Violation) until
10 minutes elapse, then Time of Day.
• If you surface due to 100% O2 without having completed the Deco obligation, the full TLBG and O2 value (100) will
ash with O2sat icon for the rst 10 minutes, then operation will enter VGM.
• Access to Dive ALTs and Gas Switching is allowed during the rst 10 minutes, then access to the NORM Surface Menu
is allowed.
---------------------------------------------------------------------------------------------------------------------------------------
GAS SWITCHING
> Switching changes FO2 related displays and calculations from one Gas (FO2) setting to another.
> Dives begin with Gas 1 and default to Gas 1 after 10 minutes on the surface following dives.
> Switching is blocked while on the surface, except during the rst 10 minutes after surfacing from a dive.
> Switch is only allowed when Dive Main screens are displayed.
> Switching is blocked during sounding of alarms.
> Switch can be performed regardless of depth.
Fig. 89 - O2 WARNING
(during audible)
Fig. 90 - O2 ALARM
Fig. 91 - O2 WARNING
(Deco, during audible)
Fig. 88 - PO2 ALARM
(Deco, after audible)
alt w/ Stop
Depth/Time