Oceanic 4.627 Scuba Diving Equipment User Manual


 
49
VTX OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-5382-r01 (10/24/14)
FT
GAS 1 GTR
PSI
980
14
48
TL
0:05
NDC
0:52
EDT
FT
GAS 1 GTR
PSI
1740
36
35
TL
AR
0:21
NDC
0:33
EDT
FT
GAS 1 GTR
PSI
540
5
68
TL
AR
0:11
NDC
0:52
EDT
FT
GAS 1 GTR
PSI
1500
32
57
TL
TURN
PRESSURE
FT
GAS 1 GTR
PSI
500
21
24
TL
END
PRESSURE
AR
FT
GAS 1 GTR
PSI
980
9
140
TL
DS
0:24
NDC
0:51
EDT
FFT
GAS 1 GTR
PSI
950
21
36
AR
TL
0:24
NDC
1:00
EDT
FT
GAS 1 GTR
PSI
840
11
136
TL
DS
0:06
NDC
0:47
EDT
DEPTH ALARM (Fig. A1)
Audible >> sounds until acknowledged, time out (10 sec), or ascent is made to a depth less than the value set.
Depth digits >> flash (red) during Audible, then solid (white).
ELAPSED DIVE TIME (EDT) ALARM (Fig. A2)
Audible >> sounds until acknowledged or time out (10 sec).
EDT digits >> flash (red) in place of normal data during the Audible, then normal data is restored.
NORM TISSUE LOADING BAR GRAPH (TL) ALARM (Fig. A3)
Audible >> sounds until acknowledged or time out (10 sec), or it decreases to 1 segment less than the value set.
TL (bar graph) >> loaded segments (their usual green, yellow colors) flash during the Audible, then return to solid.
TURN PRESSURE ALARM (TMT 1 only) (Fig. A4)
Audible >> sounds until acknowledged or time out (10 sec).
Pressure digits >> flash (yellow) until the Audible is silenced, then return to solid (normal color, light blue).
Graphic >> TURN PRESS flashes (yellow) in place of normal data during the Audible, then normal data is restored.
END PRESSURE ALARM (TMT in use) (Fig. A5)
Audible >> sounds until acknowledged or time out (10 sec).
Pressure digits >> flash (red) until the Audible is silenced, then return to solid (normal color, light blue).
Graphic >> END PRESS flashes (red) in place of normal data during the Audible, then normal data is restored.
NORM DIVE TIME REMAINING (DTR) ALARM (Fig. A6)
Audible >> sounds until acknowledged or time out (10 sec).
DTR digits & icon >> flash (red) until the Audible is silenced, then return to solid (normal color, green).
ASCENT ALARM (Fig. A7)
Audible >> sounds until acknowledged or time out (10 sec) or ascent rate is slowed.
AR (bar graph) >> all 5 segments (green, yellow, red) flash until Ascent Rate is slowed, then return to solid.
GAS TIME REMAINING (GTR) WARNING (at 5 min) (Fig. A8)
Audible >> sounds until acknowledged or time out (10 sec), or GTR > 5 min.
GTR digits & icon >> flash (yellow) until the Audible is silenced and GTR > 5 min, then return to solid (normal color, green).
Fig. A1 - DEPTH ALARM
Fig. A2 - EDT ALARM
Fig. A3 - TL ALARM
Fig. A4 - TURN ALARM
Fig. A5 - END ALARM
Fig. A6 - DTR ALARM
Fig. A7 - ASCENT ALARM
Fig. A8 - GTR WARNING