10 C2473M-C (8/06)
Figure 5. Coaxitron Controller with UTP Video – Passive Receiver Only
NOTES:
• Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.
• The maximum wire gauge allowed for UTP is 16 AWG.
• Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.
COAXITRON
CONTROLLER
VC-UTP
TX+ TX- RX+ RX-
24 VAC+
24 VAC-
24 VAC+
24 VAC-
RX- RX+ TX- TX+
UTP- UTP+
RX- RX+ TX- TX+
UTP- UTP+
UTP- UTP+
UTP- UTP+
IPS-RDPE-2
VIDEO
OUT
VIDEO
IN
POSITIONING SYSTEM
POWER
TO
POWER
SUPPLY
PTZ CONTROL AND
SOFTWARE UPLOAD