To view video, control pan/tilt/zoom, or upload revised operating software and language files to a positioning system, do the following:
1. Open the door of the IPS-RDPE-2. Opening the door will automatically disconnect the controller at the head-end and trigger an audible alert
at the IPS-RDPE-2 site.
NOTE: The audible alert indicates that the data port is in service mode and also serves as a reminder to close the door after servicing the
positioning system.
2. Connect the RJ-45 connector of the IPS-CABLE (not supplied) to the RJ-45 port in the IPS-RDPE-2. The audible alert will stop.
To service and/or test the positioning system, refer to the manual supplied with IPS-CABLE. The IPS-CABLE manual includes instructions for
on-site setup, testing, and software uploads using the RJ-45 port of the IPS-RDPE-2 with a Windows-based PC, Palm OS-compatible hand-
held, or iPAQ pocket PC.
NOTE: During software/language file upload, an icon will appear on the monitor at the head-end to indicate data is being transferred to
the positioning system (refer to Figure 12). The default setting for data transmission is 115.2 kb per second. Noisy and long-run connections
will slow the transmission rate.
3. When servicing/testing is completed, disconnect the IPS-CABLE. The audible alert is triggered. Close the door to the IPS-RDPE-2 to stop the
audible alert and return control to the head-end.
Figure 12. Upload Icon
WARNING: To prevent damage to the positioning system, never cycle power or attempt control of the system during the
upload process. The upload process is not complete until the system reboots.