Sample valve: Allows for sampling of raw water.
Shut-off valve: Required to allow maintenance of pre-treatment equipment.
Pre-treatment (illustrative only): For the UV system to operate effectively, the water should meet certain
water quality parameters, as outlined below. To meet these, pre-treatment of the water may be required. Pre-
treatment equipment must be installed BEFORE the UV chamber. Pre-treatment systems can be comprised of
one or more of the following elements: sediment filters; carbon filters; iron removal systems; water softeners;
cyst reduction filters, etc.
Water Quality Requirements:
Iron: < .3 PPM (.3 mg/L)
Hardness: < 120 PPM (7 Grains Per Gallon)
% UVT: > 75%
Tannins: < 0.1 PPM
1
2
3
4
5
Bypass shut-off valve: Bypass line and valve are optional. Intended to provide emergency water supply in the
event that the UV system is unavailable.
Shut-off valve: Required to allow maintenance of UV system.
Sample valve: Allows for sampling of water entering UV chamber; necessary in order to confirm water being
treated is of adequate quality.
UV chamber: Provides disinfection of the water. Must install Plus model chambers vertically.
CoolTouch
TM
valve: Drains water from the chamber that’s been warmed by the lamp during periods of no flow.
Flow Restrictor: Restricts water from flowing over the maximum NSF certified flow rate ensuring an adequate
UV dose is maintained.
Sample valve: Allows for sampling of water immediately following UV treatment; necessary in order to
confirm proper operation of UV system.
Solenoid valve: Optional piece of equipment supplied by VIQUA for PUV-8 and PUV-16 models. Must be used
with a junction box. Allows water supply to be shut-off when proper purification cannot be
assured.
Note: If the ground from your electrical panel is tied to your copper water lines, and
you are using a solenoid valve, installation of an approved ground strap is required. This
ground strap will maintain continuity between the lines that have been cut to install the
solenoid. Check your local electrical code for the correct clamp and cable size.
Shut-off valve: Required to allow maintenance of UV system.
Junction box: An optional piece of equipment for PUV-8 and PUV-16 models. Powers solenoid valves, remote
alarms and auto-dialers.
Power supply: Powers and controls the UV lamp and other devices. Provides human interface, displaying
information and allowing control inputs (such as muting the audible alarm).
Power source: Provides power to the power supply. For safety reasons the outlet must be protected by a
Ground Fault Circuit Interrupter (GFCI). NOTE: to protect the power supply, a UL1449 certified
(or equivalent) transient voltage surge suppressor is required.
6
7
9
10
12
11
13
IMPORTANT:
A 5 micron (nominal) sediment filter must be installed
before the UV system and after any water softening equipment
14
15
OPERATION
8
8