SUPERSERVER 6025B-3/6025B-3R User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6025B-3/6025B-3R
into a rack unit. If the 6025B-3/6025B-3R has already been mounted into a rack,
you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on
the market, which may mean the assembly procedure will differ slightly. The follow-
ing is a guideline for installing the system into a rack with the rack rails provided.
You should also refer to the installation instructions that came with the rack unit
you are using.
Installing the Chassis Rails
You should have received four rack sections with the 6025B-3/6025B-3R consist-
ing of two long and two short rails sections. These secure directly to the chassis.
All screws and hardware mentioned in the installation steps should be included in
the hardware kit.
Position the chassis rail sections alongside of the chassis making sure the screw
holes line up - the long sections to the front of the chassis and the sorter ones to
the rear. Note that these rails are left/right speci c. Screw the rails securely to the
chassis (see Figure 2-1). There should be two screws for each section. Repeat
this procedure for the other rail on the other side of the chassis. You will also need
to attach the rail brackets when installng into a telco rack.
Locking Tabs: The chassis rails have a locking tab, which serves two functions.
The rst is to lock the server into place when installed and pushed fully into the
rack, which is its normal position. Secondly, these tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.