Xantrex Technology 806-1840-01 Marine Battery User Manual


 
975-0390-01-01 31
Invert Power Derating vs. Ambient Temperature
If the unit is in inverter mode and in elevated ambient temperature
above 25 °C, you will have to reduce power draw according to the
following chart to avoid over-temperature shutdown.
25 30 35 40 45 50
750
800
850
900
1000
@12.5 volts
30°C
900 watts
800 watts
750 watts
850 watts
~33°C
@11.5 volts
Freedom HF 1000/1055
watts
°C
25 30 35 40 45 50
1000
1100
1300
1400
1500
@12.5 volts
30°C
1100 watts
1000 watts
@11.5 volts
Freedom HF 1500
watts
°C
1350 watts
1450 watts
Freedom HF InvChg Owners Guide.book Page 31 Tuesday, April 29, 2014 12:10 PM