Xantrex Technology 806-1840-01 Marine Battery User Manual


 
975-0390-01-01 35
Warning Messages
Warning messages in the form of audible alarms and error codes
that appear on the display panel screen to alert you to an impending
system change. Warnings do not affect operation.
With the exception of the error codes displayed on the screen, only
the audible alarm can be turned ON or OFF. Follow the steps in “To
adjust the alarm setting:” on page 13 to change the alarm settings.
The error codes are listed in Table 7 below. The text in the Error
Code column appears on the display screen of the display panel.
Table 7
Error Codes Displayed on the Display Panel Screen
Error Code Condition Mode Action
 Low battery voltage shutdown
is imminent depending on the
setting, see “Operating Limits”
on page 22.
Inverting Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
 High battery voltage shutdown
> 15.5 volts DC
Inverting Check for external charging sources, such as an over voltage
alternator, and disconnect if necessary.
 AC output overload shutdown Inverting Reduce the loads connected to the AC outlet of the unit.
Check appliances that have high-surge ratings and disconnect if
necessary.
 Over-temperature shutdown Inverting Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille is not blocked.
Check for ambient temperature and move the unit to a cooler
location whenever possible.
Freedom HF InvChg Owners Guide.book Page 35 Tuesday, April 29, 2014 12:10 PM