Xantrex Technology 806-1840-01 Marine Battery User Manual


 
43 Freedom HF Owner’s Guide
Specifications
NOTE: Specifications are subject to change without prior notice.
Physical Specifications 1000-watt models 1500 and 1800-watt models
L × W × H 15.5” (393mm) × 9.5” (241mm)× 4.2” (106mm) 18” (457mm) × 9.5” (241mm)× 4.2” (106mm)
Net Weight 10 lbs (4.5 kg) 12.8 lbs (5.8 kg)
NOTE: Excludes any external AC or DC wiring
harnesses included on some models.
Environmental Specifications 1000-watt models 1500 and 1800-watt models
Ambient Temperature:
Operating Temperature Range
Storage Temperature Range
0–40 ºC
-20–60 ºC, with output derated above 25 °C
-40–70 ºC
Humidity: Operation/Storage 5–95% RH, non-condensing
System Specifications 1000-watt models 1500 and 1800-watt models
Transfer relay rating 30A, 2.0hp
Transfer time <30ms (milliseconds)
Transfer on bad voltage 90–100V for low AC and 130–140 for high AC
Cooling Fan, activated by any of the following:
•High internal temperature
•High AC output power
Freedom HF InvChg Owners Guide.book Page 43 Tuesday, April 29, 2014 12:10 PM