Yamaha VXR Marine Sanitation System User Manual


 
Trouble recovery
94
(2) Remove the electrical box cover.
(3) Loosen the cap on the electrical box and
remove it.
(4) Replace the blown fuse with the spare
fuse of the correct amperage by using the
fuse puller on the reverse side of the cap.
WARNING! Do not use fuses of a dif-
ferent amperage than recommended.
Substitution with a fuse that has an
improper rating can cause extensive
electrical system damage and possi-
ble fire.
[EWJ00802]
(5) Securely install the cap by tightening it
until it stops.
(6) Securely install the electrical box cover in
its original position.
1 Electrical box cover
1
1 Electrical box
2 Spare fuse
3 Fuse
4 Cap
1 Fuse puller
Fuse amperage:
Battery fuse:
30 A
Main relay drive fuse:
10 A
Electronic throttle valve fuse:
10 A
Security system fuse:
3 A
Main fuse:
20 A
1
2
4
3
UF2M11E0.book Page 94 Monday, July 11, 2011 10:21 AM