A SERVICE OF

logo

76 Technical Specifications ELS100-24TX
Table A-1. Power Cord Set Requirements by Country
Note 1
Flexible cord must be <HAR> Type HO5VV-F or HO3VV-F, 3-conductor,
1.0 mm
2
, or 0.75 mm
2
conductor size. Power cord set fittings (appliance
coupler and wall plug) must bear the certification mark of the agency
responsible for evaluation in the country where it will be used.
Note 2
Flexible cord must be Type SV, SJ, SPT or equivalent, No. 18 AWG,
3-conductor. Wall plug must be a two-pole grounding type with a NEMA
5-15P (15A, 125V) or NEMA 6-15P (15A 250V) configuration.
Note 3
Appliance coupler, flexible cord, and wall plug must bear a "T" mark and
registration number in accordance with the Japanese Dentori Law.
Flexible cord must be Type VCT or VCTF, 3-conductor, 0.75mm
2
conductor size. Wall plug must be a two-pole grounding type with a
Japanese Industrial Standard C8303 (15A, 125V) configuration.
Country Accredited Agency See Notes *
Australia EANSW 1
Austria OVE 1
Belgium CEBC 1
Canada CSA 2
Denmark DEMKO 1
Finland FIMKO 1
France UTE 1
Germany VDE 1
Italy IMQ 1
Japan JIS 3
Netherlands KEMA 1
Norway NEMKO 1
Sweden SEMKO 1
Switzerland SEV 1
United Kingdom BSI 1
United States UL 2
The note column includes a number. Associate this number
with the corresponding notes listed after the table to obtain