ClearOne comm GT1524 SONAR User Manual


 
Installation ~ LCD Programming
14
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Ring Indication.
An audible ring indicator, sent to the PA output, can be enabled
or disabled under this menu.
Unit ID Number
The Unit ID # allows you to view the read-only unit address set at the factory. This
unique ID number identifies that particular unit and cannot be changed.
Meters
There are five main submenus under the meter menu tree: Inputs, Outputs,
ERL/TERL, ERLE/TERLE, and Default Meter. The first four submenus are all
handled in the same way.
Inputs, Outputs, ERL/TERL, and ERLE/TERLE
Referencing the LCD, press the Meter button, then scroll through the options (Inputs,
Outputs, ERL/TERL and ERLE/TERLE) to specify which is to be metered by the
front-panel LED meter. When the appropriate option is visible, press Enter to begin
monitoring its status on the front panel LCD. All items under this menu can be
scrolled through by pressing the /arrows.
Default Meter
The default meter parameter determines what is being displayed on the LED meter
when the GT1524 times out.
Timeout
The GT1524 has a system mode called Timeout. This parameter can be adjusted
through the RS-232 port only using the TOUT command. Timeout controls the delay
time (in minutes) before the LCD panel will automatically switch back to the title
screen and default meter. The range is 0–15 minutes. Default is 10 minutes; 0
disables this mode.
Disabling the timeout will
allow the GT1524 to
remain in the same
position in the LCD menu until the
LCD menu is manipulated again.