Furuno 2837sw Marine RADAR User Manual


 
2-1
2. WIRING
2.1 Interconnection
Wiring consideration
To lessen the chance of picking up electrical interference, avoid where possible routing the
signal cable near other onboard electrical equipment (radars, transmitting radio antennas,
etc.) Also avoid running the cable in parallel with power cables. When crossing with other
cable, the angle should be 90°to minimize the magnetic field coupling.
The signal cable between the antenna and processor units is available in lengths of 15 m,
30 m, 40 m and 50 m. Whatever length is used, it must be unbroken; namely, no splicing
allowed. Use the signal cable as short as possible to minimize attenuation of the signal.
The radar should be connected to an emergency power source, as required by SOLAS II-1.
FCR-2827W/2827W-D
Radar Processor unit
100-115 VAC/220-230 VAC
TB801
TB802
RW-9600
15/30/40/50 m
(Max.100 m)
DPYC-2.5
Junction Box
RJB-001*
Junction Box
RJB-001*
: Cable requires fabrication
F4
F3
F2
F1
F4
F3
F2
F1
24 VDC
100/230 VAC
DSUB9P-DSUB9P cable
5 m/10 m
XH10P-DS-5P cable
(10 m/20 m/30 m)
or
XH10P-W-5P-A cable
(10 m/20 m/30 m)
HUB-100
LAN Adapter
EC-1010
Chart
Processor Unit
EC-1000C
TTYCS-1
TTYCS-1
TTYCS-4
EPFS
TTYCS-1
MPYC-7
MOD-Z072-020+
cable
(2 m)
B Adapter
EC-1020
Control unit
RCU-020
Remote Control Unit
RCU-016
100-230 VAC
100-230 VAC
DVI-D/D SINGLE LINK cable or RGB (HD15)
5 m/10 m
MU-231CE
(FCR-2827W)
MU-231
(FCR-2827W-D)
DPYCY-1.5
MOD-Z072-020+ cable
(2 m)
Other Radar
DPYCY-1.5
24 VDC
100/230 VAC
PR-62
PR-62
ALARM
OUT
or
HUB-100
PWR Control cable
GYRO
(SYNCHRO,
STEPPER, or
IEC61162-2)
ALARM OUTPUT
TTYCS-1
DPYCY-1.5
24 VDC
100/230 VAC
PR-62
EPFS
LOG/DUAL-AXIS LOG
AIS
ALARM
TTYCS-1
LAN Adapter
EC-1010
RPU-016
Antenna unit
TB803
Waveguide
WRJ-9
or
FR-9
TB803
RU-3305
100 VAC,
1φ
, 50/60 Hz
For De-icer
110/115/
220/230 VAC,
1φ
, 50/60 Hz
Transceiver
unit
RTR-081
MPYCY-19
(Max. 30m)
ALARM
Control unit
RCU-015FEA
*: If the cable run between the
antenna unit and radar processor
unit is more than 100m, use Junction
box RJB-001. However, the maximum
length is 300m.
Standard Interconnection (FCR-2827W/2827W-D)