Furuno RP-250 Marine GPS System User Manual


 
9. INSTALLATION OF VIDEO PLOTTER KIT
53
b) Insert supplied floppy disk in the PC, execute the “upe.bat” file. The PC
displays “TARGET POWER ON.”
c) Turn on the display unit to load the program. The PC displays “Finish Version
up.ted” when the loading is completed.
d) Disconnect the PC connection cable.
e) While pressing and holding down the [HL OFF] key, press the [RADAR
MENU] key five times.
f) Press [RADAR MENU], [0], [0], [0], [2], [0], [0], [0], [0].
g) Press the [ENTER] key five times.
h) Turn the power off and on. “Initializing” appears on the display for about 90
seconds.
i) Confirm RP program no. by pressing the [RADAR MENU], [0], [0], [0], [3] and
[ENTER].
**: Program number
*1: 03591870** for C-MAP specification
FR-2105 TEST
PROGRAM NO ROM RAM CRAM DISPSW
MAIN 03591840** OK OK 1234
ARP 18590381** OK OK OK 0000
DSP 18590391** OK OK OK
RP-1
03591860**, *1 OK OK OK 00
RP-2
03591880** OK OK 00
DRAM OK OK
RP BOARD BAT OK SIO - -
RP CARD 1 OK CARD 2 OK
CARD 1 BAT OK CARD 2 BAT OK
ANTENNA SPEED 23.8 RPM
TRIG FREQ 143.2 Hz
MAG CURRENT 11.1 V
R. MONITOR 1.8 V
TUNE IND 0.8 V
1 2 3 002
2 5 1




0 0 8

To quit press [STBY/TX] key twice.
Test results
16. Retract the stay to close the display unit.
17. Push in the monitor until you hear a “click.”
18. Refasten bolts removed at step 2.
19. Refasten the right and left arm covers.