38 GHP 10 Marine Autopilot System Installation Instructions
Advanced Conguration Power-on Procedure
Advanced conguration options are not available on the GHC 10 under normal conditions. To access the advanced conguration
settings of the GHP 10, use the advanced conguration power-on procedure.
To access the wizards and advanced conguration options:
1. With the power off, press both the center and the right soft keys on the GHC 10.
2. While pressing the center and the right soft keys, power the GHC 10 on.
3. Press all 3 buttons until the heading screen appears. Release the buttons.
To make sure the wizards and advanced conguration options are available:
1. From the heading screen, select Menu > Setup.
2. If the option for Dealer Autopilot Conguration is available, you correctly performed the
advanced conguration power-on procedure.
Manually Running the Dockside and Sea Trial Wizards
The Dockside Wizard and the Sea Trial Wizard allow you to quickly dene all of the important conguration settings on the GHP 10.
If, after running the wizards, you do not feel as though the GHP 10 is working correctly, you can run the wizards again at any time. To
access the wizards, power the GHC 10 on using the advanced conguration power-on procedure.
To manually run the Dockside Wizard:
1. From the Heading screen, select Menu > Setup > Dealer Autopilot Conguration > Wizards > Dockside Wizard.
2. Perform the steps as prompted. For more information, see page 35.
To manually run the Sea Trial Wizard:
1. From the Heading screen, select Menu > Setup > Dealer Autopilot Conguration > Wizards > Sea Trial Wizard.
2. Perform the steps as prompted. For more information, see page 35.
Changing Advanced Conguration Settings
You can run the Autotune automated conguration process, calibrate the compass, and dene north on the GHP 10 through the
GHC 10 without running the wizards. Additionally, without running the wizards, you can individually dene each conguration
setting. To access the automated conguration settings and the advanced conguration settings, power the GHC 10 on using the
advanced conguration power-on procedure
To manually run the automated conguration settings:
1. From the Heading screen, select Menu > Setup > Dealer Autopilot Conguration > Automated Setup.
2. Select Autotune, Calibrate Compass, or Set North.
3. Perform the steps as prompted. For more information on each automated conguration setting, see page 35.
To manually dene individual conguration settings:
1. From the Heading screen, select Menu > Setup > Dealer Autopilot Conguration.
2. Select the appropriate category of setting you want to congure.
3. Select the setting you want to congure. Refer to the description of each setting on
page 39.
Advanced Conguration
Power-on Procedure
Hold these
soft keys
and power the
GHC 10 on
Advanced Conguration
Power-on Procedure
Hold these
soft keys
and power the
GHC 10 on