Graco 308-017 Marine Sanitation System User Manual


 
2 308-017
SAFETY
W
ARNINGS
HIGH
PRESSURE FLUID CAN CAUSE SERIOUS INJUR
Y
. FOR PROFESSIONAL USE ONL
Y.
OBSER
VE ALL W
ARNINGS. Read And Understand All Instruction Manuals Before Operating Equipment.
MOVING
P
ARTS HAZARD
KEEP
HANDS AND FINGERS A
WA
Y FROM THE PRIMING PIST
ON
DURING OPERA
TION AND WHENEVER THE PUMP IS CHARGED
WITH
AIR to reduce the risk of injury!
On the pump downstroke the
priming
piston extends beyond the intake cylinder
to pull the material into
the
pump. The priming
piston works under extreme force. During opera
-
tion
and whenever the pump is charged with air
, the priming piston can
severely
injure or amputate a hand or finger
, or break a tool, caught be
-
tween
it and the intake cylinder
. Always
follow the
Pressure Relief Pro
-
cedure,
below
, before checking, clearing, cleaning, flushing or
servicing
any
part of the pump.
The
air motor piston (located behind the air motor plates or shield ) also
moves
when air is supplied to the motor
. NEVER operate the pump with
the
air motor plates or shield removed.
Before servicing the pump, follow
the
Pressure Relief Procedure
below to prevent the pump from
starting
accidentally.
FLUID INJECTION HAZARD
General
Safety
This
equipment
generates very high fluid pressure. Spray from the spray
gun/dispensing valve, leaks or ruptured components can inject fluid
through
your skin and into your body and cause extremely serious bodily
injury,
including the need for amputation. Also, fluid injected or splashed
into
the eyes or on the skin can cause serious damage.
NEVER
point
the spray gun/dispensing valve at anyone or at any part of
the
body
. NEVER put hand or fingers over the spray tip/nozzle.
ALWA
YS have the tip guard in place on
the spray gun when spraying.
ALWAYS
follow the
Pressure Relief Procedure
, right, before
cleaning
or
removing the spray tip/nozzle or servicing any system equipment.
NEVER try to stop or deflect leaks with your hand or body
.
Be
sure all equipment safety devices are operating properly before each
use.
Medical
Alert––Airless Spray W
ounds
If
any fluid appears
to penetrate your skin, get
EMERGENCY MEDICAL
CARE
A
T
ONCE. DO NOT TREA
T AS A SIMPLE CUT
. T
ell the doctor
exactly
what fluid was injected.
Note
to Physician:
Injection in the skin
is a traumatic injury
.
It is im
-
portant
to treat the injury surgically as soon as possible
. Do
not
delay
treatment to research toxicity
. T
oxicity is a concern with some ex
-
otic
coatings injected directly into the blood stream. Consultation with a
plastic
surgeon or reconstructive hand surgeon may be advisable.
Spray
Gun/Dispensing V
alve Safety Devices
Be sure all spray gun/dispensing valve safety devices are operating
properly
before each use. Do not remove or modify any part of the
gun/
valve;
this can cause a malfunction and result in serious bodily injury
.
Safety
Latch
Whenever
you stop spraying/dispensing, even for a moment, always
set
the
spray gun/dispensing valve safety latch in the closed
or “safe” posi
-
tion,
making the gun/valve inoperative. Failure to set the safety latch can
result
in accidental triggering of the gun/valve.
Trigger
Guard (if present)
Never
operate the spray
gun/dispensing valve with the trigger guard re
-
moved.
This guard
helps prevent the gun/valve from triggering acciden
-
tally
if it is dropped or bumped.
Diffuser
(only on spray guns)
The
spray gun dif
fuser breaks up spray and reduces the risk of fluid injec
-
tion
when the tip is not installed. Check the dif
fuser operation regularly
.
Follow the Pressure Relief Procedure, to the right, then remove the
spray
tip. Aim the spray gun into a grounded metal pail, holding the spray
gun firmly to the pail. Using the lowest possible pressure, trigger the
spray
gun. If
the fluid emitted is not dif
fused into an irregular stream, re
-
place
the dif
fuser immediately
.
Tip
Guard (only on spray guns)
ALWAYS
have the tip guard in place on the spray gun while spraying. The
tip
guard alerts you to the fluid injection hazard and
helps reduce,
but
does
not prevent,
the risk of accidentally placing your fingers or any part
of
your body close to the spray tip.
Spray T
ip/Nozzle Safety
Use
extreme caution when cleaning or
changing spray tips/nozzles. If the
spray
tip/nozzle clogs while
spraying/dispensing, engage the spray gun/
dispensing
valve safety latch immediately
. AL
WA
YS follow the
Pressure
Relief
Procedure
and then remove the spray tip/nozzle to clean it.
NEVER wipe off build-up around the spray tip/nozzle until pressure is
fully
relieved and the
spray gun/dispensing valve safety latch is engaged.
Pressure
Relief Procedure
To
reduce the risk of serious bodily injury
, including fluid injection,
splashing
in the eyes or on the skin, or injury from moving parts,
always follow this procedure whenever you shut of f the pump,
when
checking or servicing any part of the spray/dispensing sys
-
tem,
when installing, cleaning
or changing spray tips/nozzles, and
whenever
you stop spraying/dispensing.
1.
Engage the spray gun/dispensing valve safety latch.
2.
Shut of
f the air to the pump.
3. Close
the bleed-type master air valve (required in your sys
-
tem).
4.
Disengage the gun/valve safety latch.
5. Hold a metal part of the gun/valve firmly to the side of a
grounded
metal pail,
and trigger the gun/valve to relieve pres
-
sure.
6. Engage
the gun/valve safety latch.
7. Open the drain valve (required in your system) and/or the
pump bleeder valve, having a container ready to catch the
drainage.
8. Leave
the drain valve open until you are ready to
spray/dis
-
pense
again.
If you suspect that the spray tip/nozzle or hose is completely
clogged,
or that pressure has not been fully relieved after following
the
steps above,
VER
Y SLOWL
Y loosen the tip guard retaining nut
or
hose end coupling and relieve pressure gradually
, then loosen
completely.
Now clear the tip/nozzle or hose.