Before Beginning Repair
3A1570A 13
Before Beginning Repair
1. Flush if necessary. See Flushing, page 14.
2. Turn main heater power OFF .
3. Relieve pressure. See Pressure Relief Procedure.
Pressure Relief
Procedure
The Fusion AP gun is shown.
1. Turn off feed pumps and agitator if used.
2. Park component A pump. Follow Park; see page 14.
3. Close the air inlet valve.
4. Engage gun piston safety lock.
5. Close gun fluid inlet valves A and B.
6. Close pump inlet supply valves.
Shutdown
1. Turn main heater power OFF .
2. Follow Park.
3. Check and fill wet-cups (AK, Z).
4. Follow gun shutdown procedure. See gun manual.
Repairing this equipment requires access to parts
that may cause electric shock or other serious injury
if work is not performed properly. Electrical
troubleshooting must be done by a qualified
electrician. Be sure to shut off all power to equipment
and lock out power at the source before repairing.