Hitachi SJ700B Marine Battery User Manual


 
= Allowed
= Not permitted
Code Function Name Monitored data or setting
Default Setting
Setting
during
operation
(allowed or not)
Change
during
operation
(allowed or not)
SJ700/SJ700D(CTmode)
SJ700B
-FE -FU -F -F -FU
Frequency Upper/Lower Limit and Jump Frequency
A061
Frequency upper limit setting
0.00 or "1st minimum frequency limit" to "maximum frequency" (Hz)
0.00 0.00 0.00 0.00 0.00
A261
Frequency upper limit setting, 2nd motor
0.00 or "2nd minimum frequency limit" to "maximum frequency, 2nd motor" (Hz)
0.00 0.00 0.00 0.00 0.00
A062
Frequency lower limit setting
0.00 or "start frequency" to "maximum frequency limit" (Hz)
0.00 0.00 0.00 0.00 0.00
A262
Frequency lower limit setting, 2nd motor
0.00 or "start frequency" to "maximum frequency, 2nd motor limit" (Hz)
0.00 0.00 0.00 0.00 0.00
A063
Jump (center) frequency setting 1
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 0.00 0.00 0.00 0.00
A064
Jump (hysteresis) frequency width setting 1
0.00 to 10.00 (Hz)
0.50 0.50 0.50 0.50 0.50
A065
Jump (center) frequency setting 2
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 0.00 0.00 0.00 0.00
A066
Jump (hysteresis) frequency width setting 2
0.00 to 10.00 (Hz)
0.50 0.50 0.50 0.50 0.50
A067
Jump (center) frequency setting 3
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 0.00 0.00 0.00 0.00
A068
Jump (hysteresis) frequency width setting 3
0.00 to 10.00 (Hz)
0.50 0.50 0.50 0.50 0.50
A069
Acceleration stop time frequency setting
0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)
0.00 0.00 0.00 0.00 0.00
A070
Acceleration stop time frequency setting
0.0 to 60.0 (s)
0.0 0.0 0.0 0.0 0.0
PID Control
A071
PID function enable
00 (disabling), 01 (enabling), 02 (enabling inverted-data output)
00 00 00 00 00
A072
PID proportional gain
0.2 to 5.0
1.0 1.0 1.0 1.0 1.0
A073
PID integral time constant
0.0 to 999.9, 1000. to 3600.0 (s)
1.0 1.0 1.0 1.0 1.0
A074
PID derivative gain
0.00 to 99.99, 100.0 (s)
0.00 0.00 0.00 0.00 0.00
A075
PV scale conversion
0.01 to 99.99
1.00 1.00 1.00 1.00 1.00
A076
PV source setting
00 (input via OI), 01 (input via O), 02 (external communication),
03 (pulse-string frequency input), 10 (operation result output)
00 00 00 00 00
A077
Output of inverted PID deviation
00 (OFF), 01 (ON)
00 00 00 00 00
A078
PID variation range
0.0 to 100.0 (%)
0.0 0.0 0.0 0.0 0.0
A079
PID feed forward selection
00 (disabled), 01 (O input), 02 (OI input), 03 (O2 input)
00 00 00 00 00
AVR
A081
AVR function select
00 (always on), 01 (always o ), 02 (o during deceleration)
00 00 02 00 02 ×
A082
AVR voltage select
200 V class: 200, 215, 220, 230, 240 (V) 400 V class: 380, 400, 415, 440, 460, 480 (V)
400
230/460 200/400 200/400 200/400
×
Operation Mode and acceleration/
deceleration function
A085
Operation mode selection
00 (Normal operation)/ 01 (Energy-saving operation)/ 02 (Fuzzy operation) (*3)
00 00 00 00 00 ×
A086
Energy saving mode tuning
0.1 to 100.0
50.0 50.0 50.0 50.0 50.0
A092
Acceleration (2) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
A292
Acceleration (2) time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
A392
Acceleration (2) time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
A093
Deceleration (2) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
A293
Deceleration (2) time setting, 2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
A393
Deceleration (2) time setting, 3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
15.00 15.00 15.00 15.00 15.00
External frequency adjustment
A094
Select method to switch to Acc2/Dec2 pro le
00 (switching by 2CH terminal), 01 (switching by setting),
02 (switching only when rotation is reversed)
00 00 00 00 00
A294
Select method to switch to Acc2/Dec2,
2nd motor
00 (switching by 2CH terminal), 01 (switching by setting),
02 (switching only when rotation is reversed)
00 00 00 00 00
A095
Acc1 to Acc2 frequency transition point
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A295
Acc1 to Acc2 frequency transition point,
2nd motor
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A096
Dec1 to Dec2 frequency transition point
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A296
Dec1 to Dec2 frequency transition point,
2nd motor
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A097
Acceleration curve selection
00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)
00 00 00 00 00
A098
Deceleration curve selection
00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)
00 00 00 00 00
A101
OI-L input active range start frequency
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A102
OI-L input active range end frequency
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A103
OI-L input active range start current
0. to "[OI]-[L] input active range end current" (%)
20. 20. 20. 20. 20.
A104
OI-L input active range end current
"[OI]-[L] input active range start current" to 100. (%)
100. 100. 100. 100. 100.
A105
OI-L input start frequency enable
00 (external start frequency), 1 (0 Hz)
00 00 00 00 00
A111
O2-L input active range start frequency
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*3)
0.00 0.00 0.00 0.00 0.00
A112
O2-L input active range end frequency
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*3)
0.00 0.00 0.00 0.00 0.00
A113
O2-L input active range start voltage
-100. to 02 end-frequency rate (%)
-100. -100. -100. -100. -100.
A114
O2-L input active range end voltage
"02 start-frequency rate" to 100. (%)
100. 100. 100. 100. 100.
Acceleration
and
deceleration
A131
Acceleration curve constants setting
01 (smallest swelling) to 10 (largest swelling)
02 02 02 02 02
A132
Deceleration curve constants setting
01 (smallest swelling) to 10 (largest swelling)
02 02 02 02 02
Operation-target frequency
A141
Operation-target frequency selection 1
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
02 02 02 02 02
A142
Operation-target frequency selection 2
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
03 03 03 03 03
A143
Operator selection
00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication: A141 x A142)
00 00 00 00 00
A145
Frequency to be added
0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)
0.00 0.00 0.00 0.00 0.00
A146
Sign of the frequency to be added
00 (frequency command + A145), 01 (frequency command - A145)
00 00 00 00 00
Acceleration
and deceleration
A150
EL-S-curve acceleration ratio 1
0. to 50. (%)
25. 25. 25. 25. 25.
A151
EL-S-curve acceleration ratio 2
0. to 50. (%)
25. 25. 25. 25. 25.
A152
EL-S-curve deceleration ratio 1
0. to 50. (%)
25. 25. 25. 25. 25.
A153
EL-S-curve deceleration ratio 2
0. to 50. (%)
25. 25. 25. 25. 25.
(*1) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz) (*2) -120. to -100., -99.9 to 0.00 to 99.99 ,100.0 to 120.0 (Hz)
(*3) SJ700D (VT mode):00 (Normal operation), 01 (Energy saving operation)
16