17
figure on the following page.) Notice how the signal strength decreases.
The second bottom signal will probably disappear and the bottom signal
intensity will likely decrease.
3. Now move the transducer around to find the best location with the
strongest possible bottom signal. If you find a spot with an acceptable
bottom signal, mark the location and move on to step 4.
If you can't get an acceptable bottom signal, try turning up the sensitivity
by three or five keystrokes and then move the transducer around once
more. If you find a spot that works, mark it and move on to step 4.
If you have to turn up sensitivity by more than five keystrokes to get a
good signal, the transducer should be mounted on the outside of the
hull. This is especially true if you have to turn sensitivity all the way
up to get a decent bottom signal.
4. Most people can get good results by following steps 1 through 3, so
this step is optional. If you want to make an extra effort to be
absolutely sure that your selected location will work under all
conditions, make a test run with the boat on plane and observe the
bottom signal. You'll need to figure some way to prop the transducer
into position while you make your test run. (A brick or two might be
sufficient to hold it in place.)
5. When you're satisfied with a location, mark it and proceed with
the installation.
Shoot-Thru-Hull Installation
If you are installing the transducer on a hull with flotation material
sandwiched within the hull, refer to the subsection "Shoot-Thru-Hull
Preparation,” beginning on page 15.
1. Make sure the area is clean, dry and free of oil or grease, then sand
both the inside surface of the hull and the face of the transducer with
100 grit sandpaper. The sanded hull area should be about 1-1/2 times
the diameter of the transducer. The surface of the hull must be flat so
the entire transducer face is in contact with the hull prior to bonding.
After sanding, clean the hull and transducer with rubbing alcohol to
remove any sanding debris.
WARNING:
Use only the epoxy available from LEI. It has been
formulated to work with these installation procedures.
Other epoxy types may be too thin or may not cure to the
right consistency for optimum transducer performance.