Lowrance electronic X67C SONAR User Manual


 
42
Backlight Level Command, left, and Backlight Level control bar, right.
The control bar appears automatically whenever you turn on the unit.
Calibrate Speed
The speed sensor can be calibrated to compensate for inaccuracies. Be-
fore you change the setting, first calculate the percentage that the
speed is off. You will enter this percentage in a moment.
For example, if you figure the sensor is reading 10 percent faster than
actual speed, you will enter – 10 in the calibration window. If the sen-
sor is reading 5 percent slower than true speed, you will enter + 5 in
the window.
Perform your test in relatively calm water free of current, if possible.
(Unless, of course, you are taking the current speed into consideration
when making your calculation.) After you have a correction figure,
here's how to enter it:
1. Press
MENU
|
MENU
| to
C
ALIBRATE
W
ATER
S
PEED
|
ENT
.
2. Enter the number you calculated earlier: press or to change the dis-
played number. Continue until the percentage is correct, then press
EXIT
.
Chart Speed
The rate that echoes scroll across the screen is called the chart speed.
The default is maximum; we recommend that you leave the speed set
there for virtually all fishing conditions.
However, you might consider experimenting with chart speed when you
are stationary or drifting very slowly. You may sometimes achieve bet-
ter images as you slow down the chart speed to match how fast you are
moving across the bottom.
If you are at anchor, ice fishing or fishing from a dock, experiment with
a chart speed around 50 percent. If you are drifting slowly, try a chart