Sterling 6017 series Marine Instruments User Manual


 
Page 12 6017 Series Hot Oil Large Temperature Control Units
Sterling stocks many lengths of flexible metal hose; the part
number is 572-16969. State the length of hose you want when
ordering.
! WARNING
Component failure may result in high-temperature
oil spray, causing serious injury or death.
Make sure hoses, valves, and other components
installed in your process can withstand maximum
temperature and pressure of the 6017 unit; check
unit nameplate for specific capacities.
All components must be carefully inspected for
condition before installing. Make sure you have
factory components if you have any doubt.
Electrical System Controls
The electrical controls of your 6017 unit are specially engineered
for reliability, safety and simplicity of operation. The switches are
clearly labeled as to their function. Your 6017 unit has a system
status board so you can evaluate the status and performance of the
unit at a glance. Pilot lights are provided to indicate key unit
functions.
An audible alarm is standard with your unit. The alarm will sound
in the event of the following conditions:
motor overload
safety thermostat trip ( over temperature )
low fluid pressure
low fluid level (optional)
high fluid level (optional)
Push the ALARM SILENCE button to silence the alarm. See
Chapter 4 for more information on control functions.