Xantrex Technology Marine Instruments Marine Instruments User Manual


 
28
In addition to reporting primary system values, the Link 10 is capable of
many other front panel functions and will also display important historical
battery data. The words below the bar graph display indicate which of
these functions you are accessing. To use these functions you must read
and understand the following section of this manual.
RESET DATA LOCK FUNC
Resetting the Link 10
RESET Resets amp hours to zero and resets the Link 10 to factory values.
To RESET the amp-hour display to zero, SELect the RESET function as
previously described. The letters
AH AH
AH AH
AH will appear in the display. Press and
hold the SET button. After five seconds the amp-hour display will be reset
to zero and the letters
ALLALL
ALLALL
ALL will appear. If you continue to hold down the
SET for another five seconds all variables and functions are reset to the
factory defaults.
RESET DATA LOCK FUNC
Front Panel Locking
LOCK Prevents user access to Set Up and Advanced Functions.
To LOCK the Link 10, SELect the LOCK function as previously described.
The letters
LOC LOC
LOC LOC
LOC will appear in the display, indicating you are in the LOCK
function. Press SET and the letters
off off
off off
off appear, indicating the front panel
is not locked. Press SET again and the letters
on on
on on
on will appear, indicating the
front panel is locked. Repeating this procedure toggles the lock off and on.
The display will report
offoff
offoff
off or
onon
onon
on, indicating Lock off or on.
Reset and Lock