Xantrex Technology Marine Instruments Marine Instruments User Manual


 
36
Alarm Functions
F10
LOW BATTERY ALARM OFF (RECHARGE) SET POINT
Once the Low Battery Alarm is activated, recharging the battery to
this point turns the alarm OFF. This recharged point must always be at
least 10% higher than Low Battery Line closure point.
DEFAULT: 70% RANGE: 0%–70% STEP: 5%
F11
LOW BATTERY ALARM ON SET POINT
Sets when the Low Battery Alarm goes ON point based on percent of
amp hours discharged. F11 is displayed as a percentage: i.e. 10 is 10%
discharged. F11 may set anywhere in its range but at least 10% below
the F10 Low Battery Alarm OFF Set Point set point.
DEFAULT: 80% RANGE: 10%–80% STEP: 5%
F10
TURNS ON Low Battery
Alarm at a set % of rate-
compensated amp hours
discharged
F11
TURNS OFF Low
Battery Alarm when
amp hours are restored
Refer to F14 in the Owner's Manual
Functions F10, F11, and F12 define operation of the Visual Low Battery
Alarm as follows:
0% Discharged
Amp-Hour
Capacity of
Battery
E.G. 100 Ah
ALARM ON
Settable Range
70% Discharged
10% Discharged
80% Discharged
ALARM OFF
Settable Range