A–2 445-0167-01-01
Electrical Specifications
1
The term “watts” has been used throughout the guide to refer to output
power. More correctly, the actual unit of power used is “VA”.
Physical Specifications with Projections
Output power at 12 VDC input
• Continuous
• Surge capacity for 5 seconds
400 VA
1
, 32 °F to 104 °F
(0 °C to 40 °C), derated
linearly to 300 VA at 122 °F
(50 °C)
800 VA
Input voltage 12 VDC nominal
10.3 to 15.3 VDC
Output voltage 120 VAC RMS ± 3 VAC
Output frequency 60 Hz ± 0.05 Hz
Output wave form Sine wave
Total harmonic distortion of output waveform <3%
High battery shutdown 15.3 ± 0.3 VDC
Low battery indication 10.7 ± 0.3 VDC
Low battery shutdown 10.3 ± 0.3 VDC
Maximum efficiency 88%
No load current draw with switch On ( )
1.25 ADC Maximum
No load current draw with switch set to Standby
()
0 ADC
Circuit breaker 7.5 AAC
Length 13.5 inches (343 mm)
Width 7.36 inches (187 mm)
Height 3.27 inches (83 mm)
Weight 10 lb (4.54 kg)