![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/3c/83c5e96a-887f-4d52-a6a3-f07bd969a4ac/83c5e96a-887f-4d52-a6a3-f07bd969a4ac-bg16.png)
xStack DGS/DXS-3300 Series Layer 3 Stackable Gigabit Ethernet Switch CLI Manual
19
show serial_port
Parameters None.
Restrictions None.
Example usage:
To display the serial port setting:
DGS-3324SRi:4#show serial_port
Command: show serial_port
Baud Rate : 115200
Data Bits : 8
Parity Bits : None
Stop Bits : 1
Auto-Logout : 10 mins
DGS-3324SRi:4#
config serial_port
Purpose Used to configure the serial port.
Syntax
config serial_port {baud_rate [115200] | auto_logout [never |
2_minutes | 5_minutes | 10_minutes | 15_minutes]}
Description This command is used to configure the serial port’s baud rate
and auto logout settings.
Parameters
baud_rate [115200] − The serial bit rate that will be used to
communicate with the management host. This parameter is fixed
at 115200.
auto_logout – The user may select a time period from the
following list which the Switch will automatically log out of the
serial port.
• never − No time limit on the length of time the console can
be open with no user input.
• 2_minutes − The console will log out the current user if
there is no user input for 2 minutes.
• 5_minutes − The console will log out the current user if
there is no user input for 5 minutes.
• 10_minutes − The console will log out the current user if
there is no user input for 10 minutes.
• 15_minutes − The console will log out the current user if
there is no user input for 15 minutes.
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure baud rate: