5.20 Temperature Setting Example
To reduce degradation of the adhesive, the delivery hose should be at a lower temperature than the applicator and
melting tank at a lower temperature than the delivery hose. When volume requirements vary, the temperature
settings for the melting tank and delivery hose may also vary. The applicator should always be set to the
recommended delivery temperature, however certain conditions may require adjustment of this setting. In this
example, the adhesive will have a recommended delivery temperature of 350° F.
Volume Requirement
:
Low Medium High
Tank Setting (°F) 300 315 325
Hose Setting (°F) 315 330 330