11-5-2
ENGINE SPEED
IS
NOT REDUCED
WHEN
LOAD
IS
OFF.
(1)
Check the distortion of the SOLENOID BRACKET as shown in step
11-5-1-(1).
(2)
Check the
FUSE
on wiring of IDLE CONTROL
UNIT.
Remove the. control panel from control box.
Check the FUSE in the fuse holder
of
IDLE COKTROL UNIT.
If fuse
is
blown, replace with a new one. (FUSE
:
0.2A)
FUSE HOLDER
Fig.
11-16
(3)
Check the wiring of SOLENOID.
Check two leads from SOLENOID are securely connected.
(4)
Check the wiring of IDLE COKTROL USIT.
Check all leads from IDLE COXTROL UXIT are securely and correctly connected.
(5)
Checking the SOLENOID.
SOLENOID
Measure the resistance between two leads from
SOLENOID.
If the resistance is larger or smaller than this
range, SOLENOID is defective,
Replace with a new one.
Fig.
11-17
-