Dell
PowerEdge R210 Technical Guide 28
5.4 Power Supply Unit (PSU) Specifications
Table 10. PSU Specifications
Feature Non Redundant PSU
Dimensions
L-210
1
mm x W-106 mm x
H-40.0 mm
Status Indicators
1 x bi-color Light Emitting
Diode
Integrated Fans None
AC Cord Rating
15 Amps @ 120 VAC, 10
Amps @ 240 VAC
Input Voltage 90 – 264 VAC
Auto-ranging Yes
Line Frequency 47–63 Hertz
Maximum Inrush Current
Under typical line
conditions and over the
entire system ambient
operating range, the inrush
current may reach 25 Amps
for 10 ms or less.
Hot-Swap Capability No
Output Power 250W
Maximum Heat Dissipation
1039 BTU per hour
maximum
Efficiency
20% to 100% Load
82–85% @115 VAC
82–85% @ 230 VAC
1
Does not include the power supply handle or ejection tab
5.5 ENERGY STAR
®
Compliance
See the ENERGY STAR Compliance results on Dell.com.
5.6 Thermal
The thermal design of the PowerEdge R210 reflects the following:
• Closed loop thermal control algorithm. Closed loop thermal control
method uses feedback temperatures to dynamically determine proper fan
speeds.
• Comprehensive thermal management. The PowerEdge R210 controls
system cooling fan speed based on several different responses from critical
components’ sensors, such as CPU temperature, DIMM temperature, inlet
ambient temperature, and system configurations. The thermal management
adjusts proper cooling ability for the system according to what the system
really needs.